Home : Library : INTERBUS Network Information

Device Profiles

Weld-COM-Profile C0 (pdf, 53K)
MMI-COM-Profile D1 (pdf, 230K)
Sensor-/Actuator-Profile 12 (pdf, 317K)
DRIVECOM Profile 22 (contains Profiles 20 and 21) (pdf, 693K)
Encoder-Profile 71 (pdf, 317K)
Process Controllers Profile 81 (pdf, 317K)
Robot Controllers Profile 91 (pdf, 67K)
Technical Guidelines & Data Sheets
INTERBUS System Technology Basics (pdf, 1,368K)
INTERBUS Cable Specifications (Data Sheet 0677A)(pdf, 7K)
INTERBUS Device Certification (Data Sheet 0666A) (pdf, 14K)
INTERBUS Common Cable Assemblies (Data Sheet 0666A (pdf, 194K))
INTERBUS Publications
To receive your copy, phone (888) 281-2871.
INTERBUS Document and Literature Guide
INTERBUS Basics
Product Index (Hard Copy)
CD ROM's
To receive your copy, phone (888) 281-2871.
Product Index
INTERBUS Implementation CD
INTERBUS Learning CD
Learning Software

IBS CMD

IBS CMD G4 is a Windows-based software package for Configuration, Monitoring and Diagnostic of the INTERBUS I/O system. It runs under Windows 3.1, 95 and NT and is supported by all Generation 4 INTERBUS System Controller (SC) and Diagnostic System Controller (DSC) boards, such as the:

  • IBS ISA SC…
  • IBS 24 ETH DSC/I-T
  • IBS PLC5 DSC/I-T
  • IBS GE 90-70 SC/I-T
  • IBS MEA SC/I-T
  • IBS S5 DSC/I-T
  • IBS S7...
  • IBS BA DSC/I-T
  • IBS VME SC…

IBS CMD G4 offers:

  • INTERBUS configuration
  • I/O data monitoring
  • Advanced INTERBUS system diagnostics

Download IBS CMD Datasheet (pdf, 332K)

Board Type Software Designation Part Number
All G4 SC or DSC controller boards IBS CMD SWT G4 E DEMO
Demo version*
(Win 3.1, 95, and NT)
2722221
IBS CMD SWT G4 E
Full version
(Win 3.1, 95, and NT)
2721442
*The CMD DEMO version is limited to operate an INTERBUS system with not more than five devices.

On most SC and DSC controllers, the configuration data can be stored in a non-volatile memory directly on the controller board. The INTERBUS configuration is then automatically executed on power-up of the controller board.

IBS CMD G4 typically runs on a LapTop PC and connects from the serial port of the PC to the RS-232 diagnostic port on the Generation 4 SC or DSC controller board with the help of a serial cable (IBS PRG CAB, P/N 2806862 ). The IBS PC ISA SC… controller boards can also communicate via the ISA bus of the host PC (if applicable).

The online-features of IBS CMD G4enables it to operate while the control program on the host system runs the application. This gives the user the advantage of real-time diagnostic information on the INTERBUS system status.

Limitations/Restrictions:
All Generation 3 (G3) controller boards (IBS…CB or IBS…DCB) require IBS CMD G3 (P/N 2721413, IBS CMD SWT G3 E).

All Generation 4 Field Controller (FC) or Remote Field Controller (RFC) require SYSTEMWORX of PCWORX.




©1999INTERBUS Club Email: info@ibsclub.com